Heating, energy and electrics

Insulating, heating, ventilating, wiring up an appliance: these calculations link a dimension (thickness, area, cable run) to a result, using the documents and data sheets that set it.

Tools in this category

Written rules, not rules of thumb

The thermal resistance of insulation comes from its thickness and its thermal conductivity. Ventilation airflow for a home is set out in official guidance. What an appliance uses is its power multiplied by the time it runs. Each calculator names the document or data sheet it applies.

Thermal resistance by thickness and conductivity

The thermal resistance R of a layer of insulation is its thickness in metres divided by its thermal conductivity λ (lambda), in W/(m·K). The higher R is, the better the layer insulates. Conductivity is printed on the label and in the product’s declaration of performance; the values in the table are worked examples, not those of a particular product.

ThicknessR at λ = 0.032R at λ = 0.035R at λ = 0.040
60 mm1.881.711.50
100 mm3.132.862.50
140 mm4.384.003.50
200 mm6.255.715.00

Results in m²·K/W. Two layers on top of each other add their resistances: 100 mm plus 60 mm of insulation at λ = 0.035 gives 2.86 + 1.71 = 4.57 m²·K/W.

Which rules apply in the UK

In England, insulation and energy use are covered by Approved Document L, ventilation by Approved Document F and electrical safety in homes by Approved Document P, with wiring to BS 7671, the IET Wiring Regulations. Heat loss for a heating design is calculated to BS EN 12831. Notifiable electrical work is done by an electrician registered with a competent person scheme, or checked by Building Control. Scotland, Wales and Northern Ireland have their own guidance.

What these calculations do not replace

Sizing a heating system properly takes a room-by-room heat loss calculation using the location and the real walls, floors and windows. The calculators give an order of magnitude and the basic rule. For a new system or a major renovation, have the calculation done by a professional.

Frequently asked questions

Are these results enough for an electrical installation?
No. They remind you of common cable sizes and voltage drop, but the installation has to meet BS 7671 in full and notifiable work must be done by a registered electrician or approved by Building Control.
Why does the heat output vary so much from one website to another?
Because it depends on the insulation, the volume being heated and the local climate. The calculator states the method and the value it uses.
How do I convert watts to kWh?
Multiply the power in kilowatts by the hours of use: a 2,000 W appliance running for 3 hours uses 2 × 3 = 6 kWh.